Cpanel Muninn HDD temperature

Default when you install Munin Cpanel lacks a few nice configs that we have to make by hand. За мен един от тях е мониторинга на температурата на дисковете.

In general, the configuration is trivial

1. We need to determine the type of our disks – it can be one of the following : they, scsi, sat[,auto][,N][+TYPE], usbcypress[,X], usbjmicron[,x][,N], usbsunplus, marvell, areca,NEITHER, 3ware,N, hpt,L/M/N, megaraid,N, cciss,N, auto, test. The easiest way to do this is through cat's “/proc / ide” or “/proc/scsi”. To me:

# cat /proc/scsi/scsi
Attached devices:
Host: scsi0 Channel: 00 Id: 00 Lun: 00
  Vendor: ATA      Model: WDC WD1003FBYZ-0 Rev: 01.0
  Type:   Direct-Access                    ANSI  SCSI revision: 05
Host: scsi1 Channel: 00 Id: 00 Lun: 00
  Vendor: ATA      Model: WDC WD1003FBYX-0 Rev: 01.0
  Type:   Direct-Access                    ANSI  SCSI revision: 05
Host: scsi4 Channel: 00 Id: 00 Lun: 00
  Vendor: ATA      Model: TOSHIBA DT01ACA1 Rev: MS2O
  Type:   Direct-Access                    ANSI  SCSI revision: 05

 

 

As you can see I have 3 ATA disk type.

2. За да почнем да следим температурата трябва да опишем в munin node дисковете ни. В файла /etc/munin/plugin-conf.d/hddtemp_smartctl добавяте записи от следният тип

# cat /etc/munin/plugin-conf.d/hddtemp_smartctl
[hddtemp_smartctl]
user root
env.drives sda sdb
env.args_sda -d ata
env.args_sdb -d ata

 

Можем да ударим тест на нашият бъдещ конфиг по следният начин

# env drives="sda sdb sdc" args_sda="-d ata" args_sdb="-d ata" args_sdc="-d ata"  /etc/munin/plugins/hddtemp_smartctl
sda.value 32
sdb.value 33
sdc.value 33

 

Ако получите стойности значи всичко е ок. Ако получите грешка трябва да проверите дали всичко правилно описано. Следва да рестартирате munin nod-а ви и да изчакте 10-15 мин да се популират малко данни и да почне да се чертае графика. You can check /var/log/munin/munin-node.log for errors and easy troubleshooting.

If you want to receive an email at a critical disk temperature, you must add a description for the critical temperature:

[example.com]
    address 127.0.0.1
    use_node_name yes
    hddtemp_smartctl.sda.critical 55
    hddtemp_smartctl.sdb.critical 55